|

Build Your Online Product Catalogs?
Product Name: |
frequency inverter,ac motor drive
|
Supply Ability: |
|
Related proudcts |
frequency inverter, ac motor drive, |
Specifications |
0.4-450kw |
Price Term: |
FOB |
Port of loading: |
Qingdao |
Minimum Order |
1set |
Unit Price: |
|
|
Item Description Input Power Supply Rated voltage standard:380v Nonstandard: 660v, 1140v, common DC bus ,DC power supply to customize. Number of phases and frequency 2-phase or 3-phase 50/60Hz(refer to rated current specification) Range Voltage:-15%~20%,frequency:¡À5%Hz Power Capacity If Power capacity is more than ten times of the drive capacity, please purchase input reactor components. Output Power Supply Rated Capacity/Current Please refer to table2-1 Over load ability Type G: 150% rated current for 1 minute, 180% rated current for 1 second; Type P: 120% rated current for 1 minute, 150% rated current for 1 second. Cooling Cooling Forced Cooling Temperature 80℃ trip Fan control Heatsink temperature> 50℃ continuous operation Main control functions control mode No sense of vector control, V/F control, Torque Control Output frequency range 0.1-600 Hz Frequency resolution Keypad setting:0.01Hz; Analog setting: 0.1Hz Frequency Accuracy Keypad setting: highest output frequency ¡À0.01%; Analog setting: max output frequency ¡À0.2% Frequency 0.5-600Hz Braking 15KW and below, with a brake unit, 18.5KW above need to connect an external braking unit. DC injection braking Brake Voltage: 0~150% rated current adjustable, allowing the 0Hz~maxmin frequency braking, time :1~50seconds adjustable. Acc/Dec time 0.1~3600.0s Low-frequency torque compensation Manuel or automatic compensation Distance If the wiring distance is more than 50m between the drive and the motor wiring, please install output reactor components Motor overheating ***ection Trips and shows E016 Standard functions Speed tracking, paused reducer, PID control, automatic speed compensation, automatically adjusts voltage output (AVR), 16 segment speed operation, torque control, frequency hopping, torque limiting, automatic multi-stage operation, U(-)SPwn control, pendulum frequency operation, two signals superimposed control, automatic reset, timer. Standard control signals Analog input Two groups of external analog inputs |
Company: |
Japan Chinsc Electric Cooperation(Asia)Limited
|
Contact: |
Ms. jessica ju |
Address: |
No.190 Jinjing Road |
Postcode: |
255000 |
Tel: |
86 533 6285668 |
Fax: |
86 533 6285668 |
E-mail: |
|
|
|
|